Candida albicans Nucleic Acid Detection Kit
Candida albicans
Pathogen DetectionProduct overview
Specific primers are designed against Candida albicans to detect it by PCR in oral and crop swabs. For molecular diagnosis of candidiasis (thrush) in pigeons, helping distinguish fungal from bacterial infection.
Applications and testing value
For auxiliary detection of Candida albicans, often associated with oral/crop plaques, difficulty feeding, prolonged antibiotic use or reduced immunity; it helps differentiate trichomonas and pigeonpox lesions.
Candida is often opportunistic; oral plaques may also be trichomonas or pigeonpox. Interpret with microscopy, culture and medication history.
Decision note: Oral plaques are not automatically Candida; differentiate trichomonas and pigeonpox. Culture/microscopy and medication history add more than a single PCR result.
Oral plaques are a clinical sign, not a diagnosis. Candida albicans can be cultured or detected by PCR, but trichomonas and pigeonpox can look similar; the report should state the sample site and method. Antifungal use before sampling may reduce detection, so record recent medication and interpret a negative result with the lesion appearance.
Reporting note: Describe the lesion and recent antifungal/antibiotic use. A positive PCR or culture should be read with the oral examination; a negative result from an old crust does not exclude Candida deeper in the crop. If antifungal treatment has already started, state the drug and duration on the submission form; this context matters when a negative result is used to rule out Candida.
Sample type and storage
Throat/cloacal swab, faeces or lesion tissue as appropriate; seal each sample separately, label clearly and ship promptly at the recommended temperature.
Interpretation and limits
Interpret the fluorescence curve, Ct value and internal control to determine whether target nucleic acid is present. A positive result does not necessarily mean clinical disease, and a negative result does not fully exclude infection. Use the batch instructions for cut-offs; this page does not claim unverified LoD or sensitivity figures.
Kits are for laboratory research and professional testing, not human diagnosis. Results should be interpreted by a veterinarian or laboratory professional with the clinical picture, sample quality and epidemiology. See theDisclaimer.
Technical notes for laboratory users
Assay format and controls. The kits use real-time PCR/qPCR chemistry with target-specific primers and a fluorescent probe, plus positive, negative and internal/amplification controls. A valid run requires the internal control to amplify and the negative control to remain clean; a target signal without a valid control should not be reported as a stand-alone positive.
Sample-to-result workflow. Collect the sample into the recommended container, extract nucleic acid with a validated method, quantify or normalise input where the instructions require it, and set up amplification in a clean pre-PCR area. Keep extraction, reagent preparation and amplified-product analysis physically separated; use filter tips and dedicated pipettes to reduce carry-over.
Batch documentation and verification. Performance depends on the sample matrix, extraction method, instrument and operator. The current batch COA or validation report should be consulted for the claimed limit of detection, specificity panel and any matrix restrictions; users should verify the assay on their own platform before reporting results. This page does not replace those documents.
Before ordering. Confirm the catalogue number, batch, 48/96-well format, storage and shipping requirements, and request the current IFU, COA and validation summary. Verify the assay on your own platform before using it for reporting.
Limitations. A positive result indicates that target nucleic acid was detected; it does not prove clinical disease, viable organisms or a specific serotype unless the assay explicitly claims that. A negative result does not exclude infection, especially with poor sampling, low organism load or PCR inhibitors. Results are for laboratory research and professional testing and must be interpreted with clinical signs, epidemiology and, where relevant, culture, isolation or sequencing.
Related kits
Pigeon Herpes Virus (PiHV) Nucleic Acid Detection Kit
Pigeon herpesvirus
Pigeon Circovirus (PiCV) Nucleic Acid Detection Kit
Pigeon circovirus (immunosuppression)
Salmonella Nucleic Acid Detection Kit
Salmonella
Pigeon Adenovirus (PiADV) Nucleic Acid Detection Kit
Pigeon adenovirus
Pigeon Paramyxovirus Type 1 (PPMV-1) RT-PCR Kit
Pigeon paramyxovirus (Newcastle disease)
Chlamydia psittaci Nucleic Acid Detection Kit
Chlamydia psittaci
Pigeon Trichomonas (PiTG) Nucleic Acid Detection Kit
Pigeon trichomonad
Pigeon Pox Virus (PiPV) Nucleic Acid Detection Kit
Pigeon poxvirus
Pigeon Rotavirus (PiRV) Nucleic Acid Detection Kit
Pigeon rotavirus
Avian Polyomavirus (APV) Nucleic Acid Detection Kit
Avian polyomavirus (with internal control)
Psittacine Beak and Feather Disease Virus (PBFDV) Detection Kit
Psittacine beak and feather disease virus