Skip to main content
SENO Biotech logoSENO Biotech

Chlamydia psittaci Nucleic Acid Detection Kit

Chlamydia psittaci

Pathogen Detection

Product overview

A fluorescent probe PCR assay designed for Chlamydia psittaci. Chlamydia psittaci is a zoonotic pathogen; this kit is used to screen pigeon lofts for chlamydial infection, and appropriate human-infection precautions must be taken throughout testing and sample handling.

Applications and testing value

For auxiliary detection of Chlamydia psittaci, associated with respiratory, ocular or systemic infection and a zoonotic risk. Screening can be considered after introduction, in dense flocks or after contact with wild birds.

Psittacosis is zoonotic, so use stronger personal protection when handling suspect samples; a positive qPCR should be read with exposure history and veterinary assessment.

Decision note: Use stronger personal protection when handling suspect samples. Interpret positives with exposure history, clinical signs and veterinary assessment; do not self-treat with human antibiotics.

Chlamydia psittaci is a zoonotic risk, so sample handling should follow heightened biosafety precautions. PCR on respiratory/conjunctival swabs or faeces detects nucleic acid, not protective immunity; a positive result should be interpreted with exposure history and veterinary assessment, and treatment decisions should not be based on PCR alone.

Reporting note: Note the sample site and any human exposure. Because this is a zoonotic agent, the report should prompt appropriate personal protection and veterinary follow-up; a positive PCR is not a treatment prescription.

Sample type and storage

Throat/cloacal swab, faeces or lesion tissue as appropriate; seal each sample separately, label clearly and ship promptly at the recommended temperature.

Interpretation and limits

Interpret the fluorescence curve, Ct value and internal control to determine whether target nucleic acid is present. A positive result does not necessarily mean clinical disease, and a negative result does not fully exclude infection. Use the batch instructions for cut-offs; this page does not claim unverified LoD or sensitivity figures.

Kits are for laboratory research and professional testing, not human diagnosis. Results should be interpreted by a veterinarian or laboratory professional with the clinical picture, sample quality and epidemiology. See theDisclaimer.

Technical notes for laboratory users

Assay format and controls. The kits use real-time PCR/qPCR chemistry with target-specific primers and a fluorescent probe, plus positive, negative and internal/amplification controls. A valid run requires the internal control to amplify and the negative control to remain clean; a target signal without a valid control should not be reported as a stand-alone positive.

Sample-to-result workflow. Collect the sample into the recommended container, extract nucleic acid with a validated method, quantify or normalise input where the instructions require it, and set up amplification in a clean pre-PCR area. Keep extraction, reagent preparation and amplified-product analysis physically separated; use filter tips and dedicated pipettes to reduce carry-over.

Batch documentation and verification. Performance depends on the sample matrix, extraction method, instrument and operator. The current batch COA or validation report should be consulted for the claimed limit of detection, specificity panel and any matrix restrictions; users should verify the assay on their own platform before reporting results. This page does not replace those documents.

Before ordering. Confirm the catalogue number, batch, 48/96-well format, storage and shipping requirements, and request the current IFU, COA and validation summary. Verify the assay on your own platform before using it for reporting.

Limitations. A positive result indicates that target nucleic acid was detected; it does not prove clinical disease, viable organisms or a specific serotype unless the assay explicitly claims that. A negative result does not exclude infection, especially with poor sampling, low organism load or PCR inhibitors. Results are for laboratory research and professional testing and must be interpreted with clinical signs, epidemiology and, where relevant, culture, isolation or sequencing.