Skip to main content
SENO Biotech logoSENO Biotech

Pigeon Herpes Virus (PiHV) Nucleic Acid Detection Kit

Pigeon herpesvirus

Pathogen Detection

Product overview

Specific primers and probes are designed against the conserved region of pigeon herpesvirus (PiHV), with a built-in UNG anti-contamination system that removes false positives caused by residual PCR aerosol. For early screening and confirmation of herpesvirus infection in pigeon lofts.

Applications and testing value

For auxiliary detection of pigeon herpesvirus, often seen with upper-respiratory signs, conjunctivitis and reactivation after stress. qPCR helps distinguish herpesvirus from other respiratory pathogens during introduction, basketing or a respiratory outbreak.

Herpesvirus can be re-shed after stress, so one negative result does not prove lifelong freedom; repeat sampling if respiratory signs appear during quarantine.

Decision note: Sample early during respiratory or conjunctival signs. Latent virus can be re-shed after stress, so one negative result does not exclude infection; repeat if needed.

Pigeon herpesvirus can remain latent in nervous tissue and recur after stress. An acute oral/conjunctival swab is more informative than a single blood sample, and a negative result during latency should be interpreted with the timing of exposure. The assay should include an internal control to flag extraction failure or PCR inhibition.

Reporting note: State whether the sample was acute or latent-phase and which site was swabbed. A negative result during latency is not proof of freedom; if the bird was stressed or exposed, repeat sampling and interpret with the clinical timeline.

Sample type and storage

Throat/cloacal swab, faeces or lesion tissue as appropriate; seal each sample separately, label clearly and ship promptly at the recommended temperature.

Interpretation and limits

Interpret the fluorescence curve, Ct value and internal control to determine whether target nucleic acid is present. A positive result does not necessarily mean clinical disease, and a negative result does not fully exclude infection. Use the batch instructions for cut-offs; this page does not claim unverified LoD or sensitivity figures.

Kits are for laboratory research and professional testing, not human diagnosis. Results should be interpreted by a veterinarian or laboratory professional with the clinical picture, sample quality and epidemiology. See theDisclaimer.

Technical notes for laboratory users

Assay format and controls. The kits use real-time PCR/qPCR chemistry with target-specific primers and a fluorescent probe, plus positive, negative and internal/amplification controls. A valid run requires the internal control to amplify and the negative control to remain clean; a target signal without a valid control should not be reported as a stand-alone positive.

Sample-to-result workflow. Collect the sample into the recommended container, extract nucleic acid with a validated method, quantify or normalise input where the instructions require it, and set up amplification in a clean pre-PCR area. Keep extraction, reagent preparation and amplified-product analysis physically separated; use filter tips and dedicated pipettes to reduce carry-over.

Batch documentation and verification. Performance depends on the sample matrix, extraction method, instrument and operator. The current batch COA or validation report should be consulted for the claimed limit of detection, specificity panel and any matrix restrictions; users should verify the assay on their own platform before reporting results. This page does not replace those documents.

Before ordering. Confirm the catalogue number, batch, 48/96-well format, storage and shipping requirements, and request the current IFU, COA and validation summary. Verify the assay on your own platform before using it for reporting.

Limitations. A positive result indicates that target nucleic acid was detected; it does not prove clinical disease, viable organisms or a specific serotype unless the assay explicitly claims that. A negative result does not exclude infection, especially with poor sampling, low organism load or PCR inhibitors. Results are for laboratory research and professional testing and must be interpreted with clinical signs, epidemiology and, where relevant, culture, isolation or sequencing.